This item is not in stock. You can reserve it by paying 30% now — delivery in 90 working days. The remaining amount is payable before the goods are dispatched.

Available with 30% deposit · delivery in 90 working days

SKU: 740300

199 €

Price excl. VAT • VAT is added at checkout if no validated VAT number is entered

Available with 30% deposit · delivery in 90 working days

🔒 Secure checkout • PCI‑DSS compliant

    • VAT-free for EU businesses With a valid VAT ID from another EU country
    • CE-compliant Machines from ISO-certified manufacturers
    • Secure payment Card, PayPal or bank transfer
    • Delivery Available with 30% deposit · delivery in 90 working days
    • 12-month warranty Register it in the customer portal · service and spare parts from us
    • Returns and complaints No fee if the product is faulty, damaged in transit or not as ordered

    10,000+ products sold across Europe 30+ years of team experience

    Automatic transfer switch generator ATS

    ATS automatic transfer switch generator box with HOUSE NET, GENERATOR, AUTO and FAILURE lights

    The SMITH ATS is an automatic transfer switch generator box that watches the mains supply. When the mains power fails, it starts the generator and switches your load over to it. When the mains power comes back, it switches the load back to the mains and stops the generator. Nobody has to be on site.

    The ATS is made for the air-cooled SMITH diesel generators 9500SE+ (7 kW), 11000SE+ (8 kW) and SDG10 (10 kW). These generators have an ATS connection on the control panel. The ATS box is connected to it with a cable and is sold separately.

    A built-in charger keeps the starter battery of the generator charged with 2 A while the generator stands by, so the battery is full when the generator has to start.

    How does the automatic transfer switch work?

    When the mains power fails, the ATS starts the generator within 2-6 seconds. After the generator has run for 5 seconds, the load is switched to the generator. When the mains power returns, the ATS switches the load back to the mains, and the generator stops after 5 seconds of running without load. Mains and generator are never connected to the load at the same time.

    What happens if the generator does not start?

    The ATS makes 3 start attempts: it cranks the engine for 3 seconds, then for 4 seconds, then for 5 seconds, with a 5 second pause between the attempts. If the generator has not started after the third attempt, the FAILURE light comes on and the fault stays recorded until an electrician checks the system and resets it.

    Control panel and operating modes

    Four lights show the state of the system: HOUSE NET (mains), GENERATOR, AUTO and FAILURE. In AUTO mode the ATS works by itself. In MANUAL mode the automatic function is off and the generator is started and stopped by hand. The cover of the box locks with a key.

    Installation of the automatic transfer switch generator box

    The ATS box hangs on a wall on its two brackets. It is connected between the mains supply, the generator and your distribution board, and to the generator control panel with a cable and a round plug. A circuit breaker must be installed on the mains cable to the ATS. The installation must be done by a qualified electrician. Before you select AUTO, start the generator once by hand to check that it runs.

    ATS specifications

    Automatic transfer switch generator ATS
    Type Automatic transfer switch generator box (ATS)
    Compatible generators SMITH 9500SE+ (7 kW), 11000SE+ (8 kW), SDG10 (10 kW)
    Generator start after mains failure 2-6 s
    Load switched to generator after 5 s of generator running
    Start attempts 3
    Return to mains automatic, generator stops after 5 s without load
    Battery charger built-in, 2 A
    Operating modes AUTO, MANUAL
    Indicator lights HOUSE NET, GENERATOR, AUTO, FAILURE
    Connection to the generator cable with round plug to the generator control panel
    Housing metal box for wall mounting, cover with key lock
    Package dimensions 400 × 295 × 205 mm
    Weight 5.7 kg
    Warranty 12 months

    Why choose the SMITH ATS?

    • Starts the generator by itself. 2-6 seconds after a mains failure.
    • Switches back by itself. When the mains returns, the load goes back to the mains and the generator stops.
    • 3 start attempts. If the generator does not start, the FAILURE light shows it.
    • Built-in battery charger. 2 A, the starter battery stays charged.
    • AUTO and MANUAL mode. The cover locks with a key.
    • Made for SMITH generators. 9500SE+, 11000SE+ and SDG10.

    If your SMITH 7, 8 or 10 kW generator is the emergency power for a house, a workshop or a farm, the automatic transfer switch generator box takes over the starting and the switching, day and night.

    Additional information

    Weight 5,7 kg
    Dimensions 0,40 × 0,295 × 0,205 m
    Parameter Specification
    Type

    Automatic transfer switch generator box (ATS)

    Compatible generators

    SMITH 9500SE+ (7 kW), 11000SE+ (8 kW), SDG10 (10 kW)

    Generator start after mains failure

    2-6 s

    Load switched to generator

    after 5 s of generator running

    Start attempts

    3

    Return to mains

    automatic, generator stops after 5 s without load

    Battery charger

    built-in, 2 A

    Operating modes

    AUTO, MANUAL

    Indicator lights

    HOUSE NET, GENERATOR, AUTO, FAILURE

    Connection to the generator

    cable with round plug to the generator control panel

    Housing

    metal box for wall mounting, cover with key lock

    Package dimensions

    400 × 295 × 205 mm

    Weight

    5.7 kg

    Warranty

    12 months

    What generators is the SMITH ATS compatible with?

    It is compatible with SMITH 9500SE+ (7 kW), 11000SE+ (8 kW), and SDG10 (10 kW) air-cooled diesel generators.

    How quickly does the ATS start the generator after a mains failure?

    The ATS starts the generator within 2 to 6 seconds after detecting a mains power failure.

    How does the ATS handle switching the load between mains and generator?

    After the generator runs for 5 seconds, the load switches to it; when mains power returns, the load switches back and the generator stops after 5 seconds without load.

    What happens if the generator fails to start automatically?

    The ATS attempts to start the generator three times with increasing crank durations; if unsuccessful, the FAILURE light activates and the fault remains until reset by an electrician.

    Can the ATS be operated manually?

    Yes, it has an AUTO mode for automatic operation and a MANUAL mode where the generator is started and stopped manually.

    Is there a battery charger included in the ATS?

    Yes, it includes a built-in 2 A charger to keep the starter battery fully charged during standby.

    What safety features does the ATS provide to prevent simultaneous connection?

    The ATS ensures that mains and generator are never connected to the load at the same time, preventing backfeed and electrical hazards.

    What installation requirements are there for the ATS?

    The ATS must be wall-mounted using its brackets, connected between mains, generator, and distribution board, with a circuit breaker on the mains cable, and installed by a qualified electrician.

    What indicators are available on the ATS control panel?

    Four indicator lights show the system status: HOUSE NET (mains), GENERATOR, AUTO mode, and FAILURE.

    How durable is the ATS housing and what security features does it have?

    The ATS has a metal box housing designed for wall mounting, with a cover that locks using a key for security.

    Summary

    • Automatic transfer switch generator box (ATS) for SMITH 9500SE+, 11000SE+ and SDG10
    • Starts the generator 2-6 s after a mains failure, switches the load after 5 s
    • Back to the mains automatically, generator stops after 5 s without load
    • 3 start attempts, then the FAILURE light
    • Built-in battery charger 2 A, AUTO and MANUAL mode
    • Wall-mounted metal box with key lock, 5.7 kg
    • 12 months warranty

    Brand

    SMITH

    Compliance

    EU Warranty

    Product Documents

    Technical Datasheet (PDF)

    Sign in to download the full technical datasheet.

    User Manual (PDF)

    Accessible to registered customers. Versioned & tracked.

    Product Certificates (PDF)

    Sign in to download the full datasheet and CE certificate.

    ATS automatic transfer switch generator box with HOUSE NET, GENERATOR, AUTO and FAILURE lights

    Automatic transfer switch generator ATS for SMITH 7, 8 and 10 kW

    199 €

    Available with 30% deposit · delivery in 90 working days

    Available with 30% deposit · delivery in 90 working days

    We Provide High-Quality Goods All Across Europe

    Explore where our products are being used by customers throughout Europe.